Three Phase STS Keypad Prepaid Energy meter

Three Phase STS Keypad Prepaid Energy meter (DTS-121A)Product ParamentersReference voltage3X57.5/100V, 3X220/380V ~400V.3X100V, 3X380VWorking voltage rangeProvisional voltage range:90%Un~110%UnExpendi

关闭
产品咨询
客服热线:400-700-9997

Three Phase STS Keypad Prepaid Energy meter (DTS-121A)

图片关键词

图片关键词

图片关键词

图片关键词

Product Paramenters
Reference voltage
3X57.5/100V, 3X220/380V ~400V.3X100V, 3X380V
Working voltage range
Provisional voltage range:90%Un~110%Un
Expending voltage range :80%Un~115%Un
Current
CT type: 3x1.5(6)A
Direct type:3x2.5(10)A,3X5(20)A,3X10(40)A, 3X15(60)A,3X20(80)A,3X30(100)A
Accuracy level
Active Class 1.0
Reactive class 2.0
Operating temperature
Regulated temperature :-25~+60c
Limit temperature:-40c~+70c
Relative humidity
≤95(no condensation
Frequency
(50±2.5)Hz/(60±2.5)Hz
Static power consumption
<1.5W, 10VA
Main Features
Energy MeasurementTotal and time-sharing forward active & reactive energy measurement

Total and time-sharing reverse active & reactive energy measurement

Save last one to sixteen months energy data 20 digit Standard Transfer Specification(STS)

Credit data transfered from a point of sale (POS) or vending system is made into a numeric token  in a 20 digit number using the Standard Transfer Specification (STS) encryption techniques, which comply with IEC62055 protocol

Load control functionWhen the residual energy is 0 or the allowable overdraft that both sides agreed, this meter will send out power-off signal to have load switch cut off power. The power will be recovered automatically after inputting new purchased energy amount.

Programmable low credit warningThe meter can be programmed for setting user credit warning threshold, When the meter’s residualenergy is equal to credit warning threshold, the meter will start the audio & video warning function in a way of warning light flashing

Tamper detectionWith event recording function (including cover-opening event, tamper event and power failure event)

Max. Demand MeasurementMeasure total and forward active & reactive maximum demand and time of occurred

Measure total and reverse active & reactive maximum demand and time of occurred

Real Time MeasurementReal-time measurement of the phase voltage, current, total active power, reactive power, apparent power, total power factor, power grid frequency

TOU4tariffs, 100holidays, 14season tables, 8time zone tables, each table on maximum 14 time zones

Event LogThe last 10 records of following events:Power-down, Programing, Cover opening, Terminal cover opening, Reverse power, Phase Fail.the records include data and time

Optical port interfaceSupport IEC62056-21 protocol, 1200bps for communication

RS-485 serial interfaceSupport IEC62056(DLMS/COSEM) protocol, 2400bps for communication

LCD displayNumber of digits value field Up to 8, Digit size 6x14.5mm

Recommend Products

图片关键词

图片关键词

图片关键词

图片关键词

图片关键词

Thanks for your attention

Any interest, can directly contact us.


Tel
Products
Cases